{"product_id":"oxygn-deptn-sensr-ng-mv","title":"OXYGN DEPTN SENSR NG MV","description":"\u003cp\u003eA beautiful vent-free gas fireplace is a luxury — but safety is the foundation it rests on. The \u003cstrong\u003eReal Fyre ODS-0003 Oxygen Depletion Sensor Pilot Assembly\u003c\/strong\u003e is the vigilant guardian your vent-free burner deserves, continuously monitoring ambient oxygen levels and automatically cutting off the gas supply if levels fall below a safe threshold. Because the only thing that should take your breath away is the view of a gorgeous flame.\u003c\/p\u003e\u003cp\u003eEngineered specifically for \u003cstrong\u003eNatural Gas\u003c\/strong\u003e applications, this ODS pilot assembly is designed for use with \u003cstrong\u003e-12 or 12M valve vent-free burners\u003c\/strong\u003e — with or without remote operation. It is fully compatible with a range of Real Fyre vent-free burner models, including the \u003cstrong\u003eG9, G10, G18, G21, G19A, and Fyreside VF9\u003c\/strong\u003e series, making it a reliable replacement or service part for your existing system.\u003c\/p\u003e\u003cp\u003eThe assembly features a \u003cstrong\u003e750 mV thermopile output\u003c\/strong\u003e with a \u003cstrong\u003e24-inch thermopile wire length\u003c\/strong\u003e, providing ample output to power your millivolt valve system without the need for external electricity. The \u003cstrong\u003e32-inch thermocouple wire\u003c\/strong\u003e offers flexible routing during installation, and the \u003cstrong\u003eM8 x 1 thermocouple connection nut\u003c\/strong\u003e ensures a secure, standardized fit. Gas connection is via a \u003cstrong\u003e3\/8-inch 24 UNF (3\/8-inch O.D.) fitting\u003c\/strong\u003e, and the built-in injector operates at \u003cstrong\u003e166W energy consumption\u003c\/strong\u003e — keeping your system efficient and consistent.\u003c\/p\u003e\u003cp\u003eSuitable for \u003cstrong\u003eall Natural Gas grades\u003c\/strong\u003e, this pilot assembly meets rigorous safety standards, carrying compliance with both \u003cstrong\u003eEuropean and CSA Norms\u003c\/strong\u003e. Whether you're performing routine maintenance or replacing a worn pilot assembly, the ODS-0003 delivers the quality and reliability that Real Fyre is known for.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eNote: This assembly is designed for Natural Gas use only. For Propane applications, please see ODS-0004 instead.\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFail-safe Oxygen Depletion Sensor (ODS) system automatically shuts off gas if oxygen levels drop\u003c\/li\u003e\n\u003cli\u003eDesigned for Natural Gas — suitable for all Natural Gas grades\u003c\/li\u003e\n\u003cli\u003e750 mV thermopile output with 24-inch thermopile wire length\u003c\/li\u003e\n\u003cli\u003e32-inch thermocouple wire length for flexible installation routing\u003c\/li\u003e\n\u003cli\u003eM8 x 1 thermocouple connection nut for a secure, standardized fit\u003c\/li\u003e\n\u003cli\u003e3\/8-inch 24 UNF (3\/8-inch O.D.) gas connection\u003c\/li\u003e\n\u003cli\u003eBuilt-in injector with 166W energy consumption\u003c\/li\u003e\n\u003cli\u003eCompatible with -12 or 12M valve vent-free burners, with or without remote\u003c\/li\u003e\n\u003cli\u003eFits Real Fyre G9, G10, G18, G21, G19A, and Fyreside VF9 vent-free burner models\u003c\/li\u003e\n\u003cli\u003eComplies with European and CSA safety norms\u003c\/li\u003e\n\u003cli\u003eFor Propane use, order ODS-0004 instead\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOxygen Depletion Sensor (ODS) Pilot Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Type\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Wire Length\u003c\/td\u003e\n\u003ctd\u003e32 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermopile Output\u003c\/td\u003e\n\u003ctd\u003e750 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermopile Wire Length\u003c\/td\u003e\n\u003ctd\u003e24 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Consumption\u003c\/td\u003e\n\u003ctd\u003e166 W (built-in injector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Connection\u003c\/td\u003e\n\u003ctd\u003e3\/8 24 UNF (3\/8 inch O.D.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Connection\u003c\/td\u003e\n\u003ctd\u003eM8 x 1 connection nut\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eComplies with European and CSA Norms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable For\u003c\/td\u003e\n\u003ctd\u003eAll Natural Gas Grades\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eFail Safe Oxygen Depletion System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItem Weight Lbs\u003c\/td\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Real Fyre","offers":[{"title":"Default Title","offer_id":45053603872976,"sku":"ODS-0003","price":152.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/www.shopsandersgas.com\/products\/oxygn-deptn-sensr-ng-mv","provider":"Shop Sanders Gas","version":"1.0","type":"link"}